Greenhouse Ventilation Fan Calculator

Exhaust fan size in m³/h and CFM for one air change per minute in summer.

Estimate only. Results follow the formulas and rules of thumb explained below. Soil, weather and varieties vary, so check them against product labels, soil tests and local growing advice.

What this calculator does

On a sunny day a closed greenhouse can heat up to well over 40 °C within an hour, which damages flowers and fruit set. Roof vents help, but in hot climates or in larger houses an exhaust fan keeps temperatures close to the outside air. A widely used rule of thumb is one complete air change per minute in summer.

How it is calculated

Volume = L × W × eave height + L × W × (ridge − eave) ÷ 2. Fan capacity (m³/h) = volume × air changes per minute × 60. CFM = m³/h × 0.5886. The equivalent rule per floor area is roughly 8–12 CFM per square foot of floor. For natural ventilation, roof vents of about one fifth of the floor area are a common estimate.

Worked example

A 3 × 2.4 m greenhouse with 1.5 m eaves and a 2.4 m ridge holds about 14 m³ of air. One air change a minute needs a fan moving about 842 m³/h (496 CFM) – about 6.4 CFM per square foot of its 7.2 m² floor. A 500 CFM fan, plus an inlet louver on the opposite end, would suit it.

Inputs at a glance

  • Greenhouse length – in meters or feet, example 3 m
  • Greenhouse width – in meters or feet, example 2.4 m
  • Eave (side wall) height – in meters or feet, example 1.5 m
  • Ridge height – in meters or feet, example 2.4 m
  • Air changes per minute (summer: 1) – a plain number, example 1

Practical tips

  • Size the inlet louver to about 1.25–1.5 times the fan's opening, so the fan isn't starved of air.
  • Place the fan on the downwind end and the inlet opposite it so air sweeps the whole house.
  • Combine ventilation with shade cloth or whitewash in mid-summer.

FAQ

Is one air change per minute always needed?

It's a rule of thumb for summer. Spring and autumn often need only a quarter or half of that.

Do fans' rated CFM match reality?

Rated flows are measured at low static pressure; louvers and screens reduce real airflow by 10–20 %.